Line 8: Line 8:
  
 Here is a link to the current test report: {{::​eps-hartschaumdaemmplatte_klassifizierungsbericht_11101112a.pdf|}} Here is a link to the current test report: {{::​eps-hartschaumdaemmplatte_klassifizierungsbericht_11101112a.pdf|}}
 +
 +
 +----
 +
 +The Swiss Fire code (BKZ) is made up of the in the tests ascertained flammability class (first number) and the smoke level (second number), for example, BKZ 4.3.
 +
 +
 +According to EN 1350-1, combustible materials may in a transitional solution be assigned to VKF classifications. The mapping tables are published by VKF Association of Cantonal Fire Insurers.
 +
 +
 +The tables provide a simplified application for the fire and smoke behavior and for burning droplets / particles of combustible materials on the basis of national fire protection directive "use combustible materials"​ and can only be used in consultation with the cantonal and municipal fire authorities,​ however, they are usually informally recognized.
 +
 +
 +EN-classification E        corresponds ​        ​VKF-classification 3
 +
 +EN-classification s3      corresponds ​        ​VKF-classification 1
 +
 +The fire code is therefore given as: **BKZ 3.1**
 +
 +
 +----
 +
 +Literature and Source: VKF Association of Cantonal Fire Insurers
 +
 +
 +Links:
 +
 +http://​www.praever.ch/​de/​bs/​reg/​info/​klassierung/​Seiten/​default.aspx
 +
 +http://​www.praever.ch/​de/​bs/​vs/​WeiterePublikationen/​Weitere%20Publikationen/​ZuordKlassierung%20VKF_EN_d.pdf
 +

In Other Languages